79
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNTAX
COMMAND ARGUMENT 1 ARGUMENT 2 ARGUMENT 3 ARGUMENT 4 RESPONSE
Diagnostic
Events
Mask
Display/Set Diagnostic Events
Mask Register
See list of the Diagnostic
Events below.
5
DM NO ARGUMENT
(read current
Diagnostic Events
Mask Register)
DM:0x9FFF
0x9FFF – diagnostic mask
(16 bits wide).
Set bit - Enable
Clear bit - Disable
<Value>
0x0000 - 0xFFFF
Set new value
NOTE: all 6 characters
are required
DM:0x9FFF
Diagnostic
Events
Latch Mask
Display/Set Diagnostic Events
Latch Mask register
See list of the Diagnostic
Events below.
6
DL
NO ARGUMENT
(read current
Diagnostic Events
Latch Mask
register)
DL:0x100F
0x100F – diagnostic latch
mask (16 bits wide).
Set bit - Enable
Clear bit - Disable
<Value>
0x0000 - 0xFFFF
Set new value to
Diagnostic Events
Latch Mask register.
NOTE: all 6 characters
are required
DL:0x100F
0x100F – diagnostic latch
mask (16 bits wide).
Set bit - Enable
Clear bit - Disable
Device Info Read device configuration info:
- full scale range (L/min)
- device function (M/C)
- input settings (V,C)
- output settings (V,C)
- low flow cut off (%F.S.)
- power up delay (sec.)
7 DI DI: 100.0,M,V,V,2.0,2
100.0 – full scale L/min
M – device function (meter)
V – input (0-5 Vdc)
V – output (0-5 Vdc)
2.0 – Low flow cut off (%F.S.)
2 flow power on delay (sec.)