86
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNTAX
COMMAND
ARGUMENT 1
ARGUMENT 2 ARGUMENT 3 ARGUMENT 4 RESPONSE
Totalizers
Sets and controls action of the
flow Totalizers.
NOTE:
Start totalizer at Flow value has
to be entered for Volumetric
and Mass flow conditions in
fraction %FS notation
(0.0 – 1.0)
Limit volume has to be
entered:
-for Volumetric flow conditions
in currently selected volume
EU
-for Mass flow conditions in
currently selected mass EU
If Totalizer hit limit event is not
required, set “Limit Volume”
value (argument 4) to zero.
Totalizers reading is stored in
EEPROM (non volatile)
memory. Power cycle will not
affect Totalizers reading.
12
T
1 (Totalizer #1)
2 (Totalizer #2)
Z
(Reset to zero)
T1Z or T2Z
V – Volumetric.
Flow Condition
<value>
(start totalizer at
flow)
Fraction %FS not.
(0.0 – 1.0)
<value>
(Limit volume
in current
Volumetric E.U.)
T1V:0.1, 0.0
or
T2V:0.1, 0.0
M – Mass.
Flow Condition
<value> (start
totalizer at flow)
Fraction %FS not.
(0.0 – 1.0)
<value>
(Limit volume
in current Mass
based E.U.)
T1M:0.1, 0.0
or
T2M:0.1, 0.0
D
(disable
totalizer)*
T1:D or T2:D
E
(enable totalizer)
T1:E or T2:E
R (read current
totalizer volume)
T1R:<value>
or
T2R:<value>
(in current EU)
S (setting status) T1S:Mode,Condition,StartFl
ow,LimitVolume
or
T2S:Mode,Condition,StartFl
ow,LimitVolume